• Phone : (+62(21) 39837477) – SMS/WA : (+628128034 1963, +6281 86 185 81)

  • English EN Indonesian ID

HAZARDOUS AREA COMPETENCY (COMPEX)
HAZARDOUS AREA COMPETENCY is  COMP’EX’ COMPETENCE BASED COURSE, 15-20 April 2020

 

A. FOREWORD

Hazardous Area Competency (COMPEX) is a course provides competence-based training and assessment for electrical and instrumentation personnel working in hazardous areas. Practical “hands-on” training and assessment takes place in a realistic simulated environment, giving attendees a comprehensive learning experience which is directly related to true industry setting. EX 01 Demonstrate ability to select appropriate cable glands for Ex d, e, n applicationsComplete a partial-installation of Ex d, e and n equipment EX02 Identify installation errors in Ex d, Ex e and Ex n equipment EX03 Complete a partial installation of Ex I equipment Understand Ex I methodology and installation requirements EX04Identify installation errors in Ex I installations

 

B. COURSE OBJECTIVES

Upon completion of this Hazardous Area Competency (COMPEX) (the CompEx Ex01-04) course the student will be able to demonstrate installation and inspections skills in hazardous areas. The participants will understand basics of Ex protection methods and where each may be used demonstrate understanding of Ex markings and understand which activities are and are not allowed with regards to maintenance and repairs.

 

C. LEARNING TECHNIQUES
In order to provide the highest quality training experience, this Hazardous Area Competency (COMPEX) training will consist of the following instructional elements Instructor led presentation, the core elements of skill will be presented and demonstrated in a classroom environment Lab exercises, practical demonstrations of skill will be accomplished by the student Final exam,  the final exam will be administered via an online service. Lab assessments will also be administered Documentation ,  the attendee will be receive a certificate is valid for 5 years

 

D. COURSE CONTENT
• General principles, ignition properties and apparatus protection, Sources of ignition
• Standards, certification and marking
• Flameproof Ex ‘d’ protection
• Increased safety Ex ‘e’ protection
• Type Ex ‘n’ protection
• Pressurisation Ex ‘p’ protection
• Intrinsic safety Ex ‘i’ protection
• Other methods of protection, Ex ‘o’, Ex ‘q’ and Ex ‘m’
• Combined (hybrid) methods of protection
• Wiring systems, enclosure entries, cable glanding and earthing
• Installation to IEC 60079-14
• Inspection and maintenance to IEC 60079-17
• Induction to competence validation testing
• Permit to work system and safe isolation

 

E. PARTICIPANTS

  • Electrical installation and inspection personel
  • Assembly manufacturers

 

F. TERM OF CONDITIONS

Times Of Training : 08:30 to 17:00

Venue: **** Hotel Jakarta and Singapore Special Requirements; Candidates are required to bring their own personal protective safety equipment

 

G. COURSE FEES

The Hazardous Area Competency training fees is USD 2250,- /delegate for 5 days Including: Training modules, merchandise, seminar kit, training certificate, coffee break & lunch, 3 days accomudation in Singapore, Return flight ticket Jakarta-Singapore. Excluding: Accommodation in Jakarta and tax

 

REGISTRATION & INFORMATION

  • Handal Consulting & Training
  • Graha Tirtadi, Jalan. Raden Saleh No. 20
    Cikini – Jakarta Pusat 10430
  • Phone : +62 21-39837475,  Fax        : +62 21-39837477
  • Info 24/7, WA/SMS : +62 812-80341963 / +62 818618581
  • Email : cs2@handaltraining.com